Study of mycotoxin calibration approaches on the example of trichothecenes analysis from flour

2012

The aim of this study was to evaluate the applicability of different calibration approaches in trichothecenes analysis from wheat flour. Concretely eight trichothecenes (five type B trichothecenes and three type A trichothecenes) were analyzed by matrix solid-phase dispersion (MSPD) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). In the first set of experiments the presence of matrix effects was evaluated; values ranged between 59% and 79%. In the second set of experiments, solutions to compensate these signal suppressions were examined. Different calibration methods showed to tackle matrix effects obtaining values between 69% and 85% for external matrix matched calibration a…

FlourWheat flourAnalytical chemistryToxicologyMass spectrometryMatrix (chemical analysis)chemistry.chemical_compoundTandem Mass SpectrometryCalibrationControl materialExternal matrix-matched calibrationMycotoxinReference standardsChromatography High Pressure LiquidTriticumInternal standard calibrationChromatographyMass spectrometryMatrix matched calibrationGeneral MedicineReference StandardsMycotoxinsDeuteriumchemistryCalibrationIndicators and ReagentsTrichothecenesFood Science
researchProduct

Non-Matrix-Matched Calibration for the Multi-Element Analysis of Geological and Environmental Samples Using 200 nm Femtosecond LA-ICP-MS: A Compariso…

2014

LA-ICP-MS is one of the most promising techniques for in situ analysis of geological and environmental samples. However, there are some limitations with respect to measurement accuracy, in particular for volatile and siderophile/chalcophile elements, when using non-matrix-matched calibration. We therefore investigated matrix-related effects with a new 200 nm femtosecond (fs) laser ablation system (NWRFemto200) using reference materials with different matrices and spot sizes from 10 to 55 μm. We also performed similar experiments with two nanosecond (ns) lasers, a 193 nm excimer (ESI NWR 193) and a 213 nm Nd:YAG (NWR UP-213) laser. The ion intensity of the 200 nm fs laser ablation was much l…

Laser ablationExcimer laserMatrix matched calibrationChemistrymedicine.medical_treatmentAnalytical chemistryMineralogyGeologyNanosecondLaserMulti elementlaw.inventionGeochemistry and PetrologyLa icp mslawFemtosecondmedicineGeostandards and Geoanalytical Research